Isıtma ve Soğutma Gün Dereceleri

Gösterim Şekli Aylık Değerlendirme Yıllık Değerlendirme


Merkez G/D Oca Şub Mar Nis May Haz Tem Ağu Eyl Eki Kas Ara Yıllık
KARS

2024
HDD 675 588 526 221 241 24 13 3 107 2398
T≤15 °C 31 29 31 25 27 7 3 1 18 172
CDD 1 1
T>22 °C 1 1
KARS

2023
HDD 774 735 426 349 233 93 26 112 276 409 589 4022
T≤15 °C 31 28 31 30 31 21 6 20 31 30 31 290
CDD 12 1 13
T>22 °C 7 1 8
KARS

2022
HDD 871 619 693 332 271 56 17 84 276 466 607 4292
T≤15 °C 31 28 31 30 30 13 4 16 28 30 31 272
CDD 2 4 3 9
T>22 °C 3 6 3 12
KARS

2021
HDD 819 584 577 265 119 47 3 98 357 476 750 4095
T≤15 °C 31 28 31 30 17 10 1 16 31 30 31 256
CDD 5 7 3 15
T>22 °C 7 3 3 13
KARS

2020
HDD 839 673 474 391 198 54 7 21 50 262 500 708 4177
T≤15 °C 31 29 31 30 26 14 2 5 12 31 30 31 272
CDD 1 1
T>22 °C 1 1
KARS

2019
HDD 810 671 613 407 168 11 12 3 142 251 551 610 4249
T≤15 °C 31 28 31 30 26 3 2 1 25 31 30 31 269
CDD 2 6 8
T>22 °C 3 6 9
KARS

2018
HDD 717 580 414 323 201 88 4 91 284 489 665 3856
T≤15 °C 31 28 31 30 31 20 1 19 31 30 31 283
CDD 5 5
T>22 °C 5 5
KARS

2017
HDD 999 839 575 376 213 64 3 38 338 508 715 4668
T≤15 °C 31 28 31 30 30 12 1 7 31 30 31 262
CDD 6 17 23
T>22 °C 6 12 18
KARS

2016
HDD 800 612 503 325 225 111 11 153 346 588 867 4541
T≤15 °C 31 29 31 30 29 19 3 22 31 30 31 286
CDD 1 1
T>22 °C 1 1
KARS

2015
HDD 768 678 564 382 226 39 3 23 19 295 498 768 4263
T≤15 °C 31 28 31 30 31 9 1 5 4 31 30 31 262
CDD 3 15 18
T>22 °C 5 11 16
KARS

2014
HDD 843 762 491 316 192 69 109 313 535 632 4262
T≤15 °C 31 28 31 30 30 14 17 31 30 31 273
CDD 1 1
T>22 °C 1 1
KARS

2013
HDD 841 690 568 335 206 106 18 8 125 370 450 918 4635
T≤15 °C 31 28 31 30 29 19 4 2 22 31 30 31 288
CDD 0
T>22 °C 0
KARS

2012
HDD 838 870 739 317 211 38 18 9 75 267 434 782 4598
T≤15 °C 31 29 31 30 31 9 5 2 18 31 30 31 278
CDD 0 0
T>22 °C 1 1
KARS

2011
HDD 746 716 611 381 249 96 16 143 352 682 852 4844
T≤15 °C 31 28 31 30 30 19 4 26 31 30 31 291
CDD 5 4 9
T>22 °C 4 4 8
KARS

2010
HDD 669 540 477 392 248 30 4 35 277 467 584 3723
T≤15 °C 31 28 31 30 31 8 1 9 31 30 31 261
CDD 4 1 5
T>22 °C 3 1 4
KARS

2009
HDD 881 608 599 433 247 107 37 85 193 282 479 620 4571
T≤15 °C 31 28 31 30 30 22 7 18 26 31 30 31 315
CDD 0
T>22 °C 0
KARS

2008
HDD 1087 894 499 298 319 158 38 3 116 312 502 803 5029
T≤15 °C 31 29 31 28 29 28 8 1 19 31 30 31 296
CDD 0
T>22 °C 0
KARS

2007
HDD 912 764 606 463 160 81 24 15 66 274 536 834 4735
T≤15 °C 31 28 31 30 25 19 6 4 13 31 30 31 279
CDD 1 1
T>22 °C 2 2
KARS

2006
HDD 908 700 545 341 204 23 133 285 522 784 4445
T≤15 °C 31 28 31 30 29 6 21 31 30 31 268
CDD 10 2 12
T>22 °C 8 2 10
KARS

2005
HDD 907 805 609 346 231 140 10 133 341 495 658 4675
T≤15 °C 31 28 31 30 31 25 3 25 31 30 31 296
CDD 2 2
T>22 °C 3 3
KARS

2004
HDD 832 684 513 423 268 99 30 3 119 288 513 935 4707
T≤15 °C 31 29 31 30 31 17 7 1 20 31 30 31 289
CDD 0
T>22 °C 0
KARS

2003
HDD 785 701 732 426 214 129 28 3 152 255 519 740 4684
T≤15 °C 31 28 31 30 31 23 7 1 24 31 30 31 298
CDD 1 1
T>22 °C 1 1
KARS

2002
HDD 960 640 531 417 285 113 21 23 61 277 482 888 4698
T≤15 °C 31 28 31 30 29 20 6 5 13 30 30 31 284
CDD 0
T>22 °C 0
KARS

2001
HDD 844 629 444 331 286 78 3 8 76 351 586 733 4369
T≤15 °C 31 28 31 30 31 13 1 2 15 31 30 31 274
CDD 6 3 9
T>22 °C 5 5 10
KARS

2000
HDD 904 836 745 312 262 108 18 90 356 510 710 4851
T≤15 °C 31 29 31 30 31 20 4 18 31 30 31 286
CDD 25 9 34
T>22 °C 12 4 16
KARS

1999
HDD 826 614 573 369 232 103 9 120 293 515 684 4338
T≤15 °C 31 28 31 30 30 22 2 20 30 30 31 285
CDD 9 9
T>22 °C 5 5
KARS

1998
HDD 884 808 590 325 210 51 5 119 276 435 655 4358
T≤15 °C 31 28 31 30 30 10 1 19 31 30 31 272
CDD 0 5 5
T>22 °C 1 5 6
KARS

1997
HDD 682 681 711 411 226 85 28 175 295 513 727 4534
T≤15 °C 31 28 31 30 30 17 6 24 31 30 31 289
CDD 0
T>22 °C 0
KARS

1996
HDD 797 755 585 411 188 158 122 326 514 545 4401
T≤15 °C 31 29 31 30 29 26 20 31 30 31 288
CDD 2 2
T>22 °C 3 3
KARS

1995
HDD 834 717 596 358 179 73 22 5 102 356 486 704 4432
T≤15 °C 31 28 31 30 24 16 6 1 13 31 30 31 272
CDD 1 1
T>22 °C 2 2
KARS

1994
HDD 888 795 611 272 203 103 9 3 68 260 521 894 4627
T≤15 °C 31 28 31 30 24 18 2 1 15 31 30 31 272
CDD 0
T>22 °C 0
KARS

1993
HDD 904 804 742 429 273 140 30 13 131 371 720 839 5396
T≤15 °C 31 28 31 30 31 24 6 3 19 31 30 31 295
CDD 0
T>22 °C 0
KARS

1992
HDD 964 881 784 440 322 169 55 37 177 302 576 830 5537
T≤15 °C 31 29 31 30 31 28 11 10 20 31 30 31 313
CDD 0
T>22 °C 0

Kontrolden geçmemiş verilerle hazırlanmıştır.

  1. G/D = Gün-Derece
  2. HDD = Isıtma Gün-Derecesi
  3. CDD = Soğutma Gün-Derecesi
  4. T≤15°C = Sıcaklığın ≤15°C olduğu gun sayısı
  5. T>22°C = Sıcaklığın >22°C olduğu gun sayısı

Gün derece, 24 saatlik periyodun ne kadarının sıcak ve ne kadarının soğuk geçtiğini ölçmeye yarayan bir birimdir.

Isıtma Gün Dereceleri [Heating Degree Days – HDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam ve oda sıcaklığını hesaba katarak soğuğun şiddetini açıklar. Birçok ülke gün derecenin hesabı için farklı tanımlar kullanır. Karşılaştırılabilir ve ortak bir kullanım oluşturmak için Avrupa Topluluğu İstatistik Ofisi (Eurostat) HDD’nin hesabı için aşağıdaki metodu önermektedir.

HDD = (18 °C - Tm) x değer Tm ≤ 15 °C (ısıtma eşiği)
HDD = 0 eğer Tm > 15 °C

Burada; Tm = Günlük ortalama sıcaklık, d= Gün sayısıdır.

Hesaplama günlük bazda yapılır. Aylık ve yıllık gün dereceler bunların toplanması ile bulunur.

ÖRNEK:
Ankara’nın 29 Aralık 2005 günü ortalama sıcaklığı 2.0°C’ dir. Buna göre:
HDD = 18-2=16 dır.

Göreceli ısıtma gün dereceleri ise güncel gün derece ile uzun dönem ortalama gün derece arasındaki orandır. Güncel gün derece / Uzun dönem ortalama gün derece

Soğutma Gün Dereceleri [Cooling Degree Days – CDD]

Belirli bir zamanda (gün, ay, yıl) dış ortam sıcaklığını hesaba katarak sıcaklığın şiddetini açıklar. Resmi olarak belirlenmiş bir eşik sıcaklık olmamakla birlikte inşaat sektörü enerji yönetim pratiklerinde eşik sıcaklık 22°C olarak alınır. Buna göre:

CDD = (Tm - 22) x değer Tm > 22 °C (soğutma eşiği)
CDD = 0 eğer eğer Tm ≤ 22°C

ÖRNEK:Ankara’nın 25 Ağustos 2005 günü ortalama sıcaklığı 25.9°C’ dir. Buna göre:
CDD = 25.9-22 = 3.9 dır.

Gün Derece toplamına neden ihtiyaç vardır?

  1. Isıtma yada soğutma gün dereceleri toplamının bilinmesi binaların ısıtılması yada soğutulması için gerekli olan enerji gereksiniminin bilinmesi açısından önemlidir. Dış ortam sıcaklığı 15°C’nin üzerinde ise ısıtma gereksizdir. Isıtma maliyeti yıllık HDD ile doğrudan orantılıdır. Bunun için 1 yıl içindeki yakıt maliyeti Yıllık HDD’ye bölünerek 1 HDD için ısıtma fiyatı çıkartılır. Daha sonraki hesaplamalar için bu indis kullanılır.
  2. HDD kış mevsiminin sertliğini göreceli olarak önceki ve uzun yıllara göre karşılaştırmak için de kullanılır.
  3. HDD aynı zamanda yeni binalar yapılırken yalıtım, ısıtma ve soğutma giderlerinin hesaplanması için inşaat sektörü tarafından ihtiyaç duyulan bir parametredir.